MECHANICAL DATA
Fixation mode
THT
Pitch
2.54mm
Number of poles
1 or 2 pole
Number of switching positions
2 max.
Mech. lifetime
20 000 operations
Electrical lifetime
min. 10 000 actuations
Function
impulse
Switching mode
break before make
Operating force
approx. 4N
Operating travel
2.5mm
Vibration
>5g
Shock test
>10g
Resistance against cleaning fluids
yes
Operating temperature
-40...+85°C
ELECTRICAL DATA
Switching voltage
60~/75-V
Contact load, dynamic
0,5A
Contact load, static
≤1A
Contact rating max.
10VA
Test voltage
500V 50Hz
Contact resistance initial
<80mΩ
Insulation resistance
>10 000MΩ
Insulations class
VDE 0110 Gr. C
ESD protection
>10kV
MATERIAL
Housing
PA6.6 GF30
Flamability
UL94V0